Always prioritize safety when operating or performing checks on the boiler.

Watch the physical dial carefully until it reaches .

The Lambert Lx 24 Fi manual provides a list of error codes to assist in diagnosing common issues. Common Error Codes

Features a 3-star energy efficiency rating per CEE/92/42 standards. Lambert Lx 24 Fi Manual English

Inspect the external terminal of the concentric flue for blockages (leaves, ice, bird nests). Ensure the vent pipes are securely connected. If the fan runs but the code remains, the venturi tube or air pressure switch needs cleaning or replacement. E05: Central Heating NTC Sensor Fault

Its wall-mounted nature (725mm height) fits well in smaller spaces like kitchens. No Smart Features:

Understanding the fundamental parameters ensures the system operates safely within designed performance boundaries. Specification Parameter Technical Value / Limit Minimum Heat Output Combustion Chamber Type Closed / Hermetic (Fan assisted) DHW Flow Rate (Δ T = 30°C) 10.7 Liters/minute DHW Temperature Adjustment Range 30°C to 60°C Maximum Heating Circuit Pressure Maximum DHW Circuit Pressure Expansion Vessel Volume Electrical Power Input 220–230V Monophase (~50Hz) Dimensions (H x W x D) 72.5 cm × 40.0 cm × 30.0 cm Net Weight 🎛 Control Panel & Operation Interface Always prioritize safety when operating or performing checks

Overheat Safety Thermostat. The boiler has become too hot. This could be due to a pump failure or air in the system.

If you have recently purchased a —a popular, high-efficiency condensing boiler used in residential and light commercial heating systems—you already know that having the original documentation on hand is critical. However, finding a clear, accessible Lambert Lx 24 Fi Manual English version can sometimes be a challenge. Whether you have misplaced your physical copy or need immediate answers to error codes, installation questions, or maintenance schedules, this article serves as a comprehensive, manual-style guide.

The boiler features a manual control system with a user-friendly interface designed for straightforward operation. Common Error Codes Features a 3-star energy efficiency

Check if the gas supply valve to the house and boiler is open. Ensure your gas meter hasn't tripped. Press and hold the Reset button. If it repeats, the ignition electrode or gas valve may be faulty. E02: Overheating Safety Thermostat Limit Exceeded Cause: The internal temperature has exceeded 105∘C105 raised to the composed with power C Fix: Wait for the boiler to cool down down below 60∘C60 raised to the composed with power C

The boiler activates solely when a domestic hot water tap is opened. The digital screen indicates live tap water temperature.

This is normal. The post-purge cycle runs for up to 3 minutes to clear residual combustion gases from the heat exchanger.

The boiler will display an error code and shut down to protect the heat exchanger. Open the black filling loop valve underneath the boiler until the needle reaches 1.2 bar, then close the valve completely.

When an error occurs, the display shows ”E” followed by a number. Below are the most frequent codes, their meaning, and user-level solutions.